DMe-211

The DMe-211 is an economical yet fully-featured contact angle meter with a computer image analysis system.

The unit combines manual droplet volume regulation, and stage up/down motion for gentle deposition of droplets with "FAMAS-basic" software controlled analysis of static and dynamic contact angle (30fps) as well as surface and interfacial tension using the pendant drop method. Analysis software to determine the surface free energy of solids is a standard feature.

Features
  • Automatic recognition of droplet deposition
  • Live image display and droplet volume monitoring
  • Movie converter
  • Manual dispenser with a set of 5 glass syringes and 5 SUS needles for precise adjustment of droplet volume and quick refilling and replacement of liquid samples
  • Fine adjustable stage in z-axis for gentle deposition of droplets without distortion
  • Adjustable level of the body and stage
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options

Hardware

  • Pendant drop kit for standard view, incl. pendant drop calibration standard
  • Surface free energy kit
Applications
  • Determination of wettability of surfaces like glass, metal, plastics, ceramics at ambient temperature
  • Surface cleanliness
  • Determination of surface and interfacial tension using the pendant drop kit (standard view)
  • Analysis of surface free energy of solids
Specifications
  DMe-211
Camera system USB2.0 CMOS camera: 30fps at 640x480 pixels
Optical system

focus: manual focus with fixed zoom
field of view: 6.3x4.7mm
Measuring methods

contact angle: sessile drop (static and dynamic)
surface/interfacial tension: pendant drop (static and dynamic)
Analysis methods



contact angle: θ/2, tangent, circle fitting, ellipse fitting
surface/interfacial tension: Young-Laplace method, ds/de method
surface free energy: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range

contact angle: 0.1 to 180°
surface/interfacial tension: 0.1 to 100mN/m
Resolution

contact angle: 0.1°
surface/interfacial tension: 0.1mN/m
Accuracy1)

contact angle: 0.3°
surface/interfacial tension: 0.3mN/m
Maximum sample surface area and height (WxDxH) 160x100x10mm

Maximum sample weight 300g
Sample stage operation:
X-axis
Y-axis
Z-axis

---
---
10mm, manually by a rotary knob
Dispenser operation:
Z-axis
Droplet generation
Dispensing resolution

---
manually, by a rotary knob
0.1μL
Droplet deposition manually, by stage operation
Dimensions (WxDxH) 170x346x283mm
Weight ca. 1.8kg
Electric power

USB bus power
DC5V, max. 500mA
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

 

 

DMs-401

The DMs-401 is a compact yet high-performance surface measuring instrument for the measurement of static and dynamic contact angles, the surface free energy of solids, and surface and interfacial tension of liquids. Its functions can be easily extended due to its sophisticated modular design. Optional accessories, such as a computer-controlled dispenser, temperature control devices, and an external tilting stage system are available.

Features

  • Automatic recognition of droplet deposition
  • Live image display and droplet volume monitoring
  • Movie converter
  • Manual dispenser with a set of 5 glass syringes and 5 SUS needles for precise adjustment of droplet volume and quick refilling and replacement of liquid samples
  • Fine adjustable stage in z-axis for gentle deposition of droplets without distortion
  • Adjustable level of the body and stage
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy

Options

Hardware

  • Jacket and heater type chambers for temperature measurements from +10 to +380℃
  • Heater type dispenser for temperature measurements from ambient to +380℃
  • Tilting stage for measurements of roll-off angles, incl. FAMAS software add-in [Sliding method]
  • Add-on module [Dynamic sliding method] for measurement of roll-off speed and roll-off acceleration. Only in combination with the tilting stage package
  • Fast image capturing system with standard 400 fps at 640x480 resolution USB3.0 CMOS camera, max. 1000fps at 640x200 resolution
  • Single automatic dispenser
  • Multi manual dispenser holder
  • Multi automatic dispenser system
  • Large capacity pump dispenser, incl. a 50ml liquid container
  • Surface free energy kit
  • Pendant drop kit (for standard & wide view)
  • Kit for captive-bubble-measurements
  • Droplet calibration standard (for wide 1 view)
  • Pendant drop calibration standard (for standard view)
  • Pendant drop calibration standard (for wide 1 and wide 2 view)

Applications

  • Determination of wettability of surfaces like glass, metal, plastics, ceramics at ambient temperature
  • Surface cleanliness
  • Determination of surface and interfacial tension using the pendant drop kit (standard & wide view)
  • Analysis of Surface free energy of solids
  • Determination of dynamic contact angles (advancing/receding angles and roll-off angle)
  • Coating property, repellency, characterization of droplet hysteresis
  • Initial spreading, absorbing property, effect of surface active agents
  • Adhesive property, characterizing surface modification, digitalization of hydrophilicity/hydrophobicity

Specifications

  DMs-401
Camera system USB2.0 CMOS camera: 60fps at 640x480 pixels
Optical system

focus: manual focus with 3 step zoom
field of view: 5.3x4.0mm, 9.6x7.2mm, 13.6x10.2mm ±6%
Measuring methods

contact angle: sessile drop (static and dynamic)
surface/interfacial tension: pendant drop (static and dynamic)
Analysis methods



contact angle: θ/2, tangent, circle fitting, ellipse fitting
surface/interfacial tension: Young-Laplace method, ds/de method
surface free energy of solids: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range

contact angle: 0.1 to 180°
surface/interfacial tension: 0.1 to 100mN/m
Resolution

contact angle: 0.1°
surface/interfacial tension: 0.1mN/m
Accuracy1)

contact angle: 0.2°
surface/interfacial tension: 0.2mN/m
Maximum sample surface area and height (WxDxH) 150x100x35mm

Maximum sample weight 300g
Sample stage operation:
Z-axis
Droplet generation
Dispensing resolution


150mm, manually by a rotary knob
---
20mm, manually by a rotary knob
(additional 20mm by stage shifting mechanism)
Dispenser operation:
Z-axis
Droplet generation
Dispensing resolution

---
manually, by a rotary knob
0.1μl
Droplet deposition manually, by stage operation
Dimensions (WxDxH) 294x461x375mm
Weight ca. 6.5kg
Electric power:
Voltage
Frequency
Power consumption

AC100-240V
50/60Hz
5.5W 15VA
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

DMo series

The four models of the DMo series are high-performance contact angle meters, only differing in their grade of automation. The high-speed camera and computer-controlled dispenser allow for precise measurements of static and dynamic contact angles, surface and interfacial tension of liquids, as well as analysis of surface free energy of solids. A wide range of options are available and lower grade models can also be upgraded later.

Each model combines the following features
  • Fast image capturing system with standard 400 fps at 640x480 resolution USB3.0 CMOS camera, max. 1000fps at 640x200 resolution
  • Automatic single dispenser system
  • 150x150mm wide sample stage with a maximum load capacity (temperature chamber + sample) of 1.4kgs
  • Stage travel distance: x-axis: 150mm, y-axis: 75mm, z-axis: fixed
  • Focusing aid with displayed index graph and value and brightness adjustment to achieve perfect focus
  • Movie converter to convert data images to MPEG-1 or AVI movie format
  • Determination of contact angles, droplet volume, residual droplet volume, sessile drop volume, height, and radius of the sessile drop
  • Measured results are displayed in a spreadsheet for easy reference and comparison, and saved in csv format for easy export to and manipulation in MS Excel
  • User-specified analysis report function, providing measurement results and parameters
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Features
  • Automatic recognition of drop deposition by FAMAS analysis software
  • Live image display and droplet volume monitoring
  • Movie converter
  • Manual dispenser with a set of 5 glass syringes and 5 SUS needles for precise adjustment of droplet volume and quick refilling and replacement of liquid samples
  • Fine adjustable stage in x- and y-axis for exact positioning
  • Adjustable level of the body and stage
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options
  • Jacket and heater type chambers for temperature measurements from +10 to +380℃ 1)
  • Heater type dispenser for temperature measurements from ambient to +380℃ 1)
  • Tilting stage for measurements of roll-off angles, incl. FAMAS software add-in [Sliding method] 1)
  • Add-on module [Dynamic sliding method] for measurement of roll-off speed and roll-off acceleration. Only in combination with the tilting stage package. 1)
  • Multi manual dispenser holder
  • Multi automatic dispenser system
  • Large capacity pump dispenser, incl. a 50ml liquid container
  • Surface free energy kit
  • Pendant drop kit (for standard & wide view)
  • Kit for captive-bubble-measurements
  • Droplet calibration standard (for wide 1 view)
  • Pendant drop calibration standard (for standard view)
  • Pendant drop calibration standard (for wide 1 and wide 2 view)
Applications
  • Determination of wettability of surfaces like glass, metal, plastics, ceramics at ambient temperature
  • Surface cleanliness
  • Determination of surface and interfacial tension using the Pendant drop kit (standard and wide view)
  • Analysis of Surface free energy of solids
  • Determination of dynamic contact angles (advancing/receding angles and roll-off angle)
  • Coating property, Repellency, Characterization of droplet hysteresis
  • Initial spreading, absorbing property, effect of surface active agents
  • Adhesive property, characterizing surface modification, digitalization of hydrophilicity/hydrophobicity
Specifications
  DMo-902 DMo-702 DMo-602 DMo-502
Camera system



USB 3.0 CMOS camera with:
400fps at 640x480 pixels
500fps at 640x400 pixels
1000fps at 640x200 pixels
Optical system

focus: manual focus with 3 step manual zoom
field of view: 6.1x4.7mm, 11.1x8.2mm, 15.8x11.8mm ±6%
Measuring methods


contact angle: sessile drop (static), advancing/receding angle (dynamic) sliding angle (dynamic) 1)
surface/interfacial tension: pendant drop (static and dynamic)
Analysis methods



contact angle: θ/2, tangent, curve fitting (ellipse, circle)
surface/interfacial tension: Young-Laplace, ds/de
surface free energy of solids: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range

contact angle: 0.01 to 180°
surface/interfacial tension: 0.01 to 100mN/m
Resolution

contact angle: 0.01°
surface/interfacial tension: 0.01mN/m
Accuracy2)

contact angle: 0.2°
surface/interfacial tension: 0.2mN/m
Maximum sample surface area and height (WxDxH) 150x150x16mm

150x150x35mm

Sample stage operation:
X-axis
Y-axis
Z-axis
Rotation axis

150mm (aut.)
75mm (aut.)
---
360° (aut.)

150mm (aut.)
75mm (man.)
---
---

150mm (man.)
75mm (man.)
---
---
Dispenser operation:
Z-axis
Droplet deposition
Droplet generation
Droplet resolution

16mm
automatic
automatic
0.1μl
35mm
automatic
automatic
0.1μl
35mm
manual
automatic
0.1μl
Dimensions (WxDxH) of:
Main instrument
Control box

297x544x305mm
290x240x86mm

288x544x305mm
260x200x70mm
Approximately weight of:
Main instrument
Control box

10.0kg
4.3kg

8.5kg
4.3kg

7.5kg
1.5kg
Electric power:
Voltage
Frequency
Power consumption

AC100-240V
50/60 Hz
115W 120VA

AC100-240V
50/60Hz
25W 48VA
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

 

 

 

 

DMo-WA series

The three models of the DMo-WA series are specially designed contact angle meters for measurements of disk-shaped substrates such as silicon wafers with a diameter of up to 300mm.

All models feature a 305mm diameter 360º rotation table and a computer-controlled dispenser which allow for automatic measurements of contact angle, advancing and receding angles, as well as analysis of surface free energy of solids.

Optional, a tilting stage for the measurement of roll-off angles is also available.

Each model combines the following features
  • Fast image capturing system with standard 400 fps at 640x480 resolution USB3.0 CMOS camera, max. 1000fps at 640x200 resolution
  • Automatic single dispenser system
  • Diameter 335mm 360º rotation sample stage with a maximum load capacity of 0.4kgs
  • Stage travel distance: x-axis: 150mm, y-axis: fixed, z-axis: fixed
  • Focusing aid with displayed index graph and value and brightness adjustment to achieve perfect focus
  • Movie converter to convert data images to MPEG-1 or AVI movie format
  • Determination of contact angles, droplet volume, residual droplet volume, sessile drop volume, height, and radius of the sessile drop
  • Measured results are displayed in a spreadsheet for easy reference and comparison, and saved in csv format for easy export to and manipulation in MS Excel
  • User-specified analysis report function, providing measurement results and parameters
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Features
  • Automatic recognition of drop deposition
  • Live image display and droplet volume monitoring
  • Movie converter
  • Automatic dispenser with a set of 5 glass syringes and 5 SUS needles for precise adjustment of droplet volume and quick refilling and replacement of liquid samples
  • Fine adjustable stage in x- and z-axis for exact positioning and gentle deposition of droplets without distortion
  • Adjustable level of the body and stage
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options

Hardware

  • Tilting stage for measurements of roll-off angles, incl. FAMAS software add-in [Sliding method] (except 902)
  • Add-on module [Dynamic sliding method] for measurement of roll-off speed and roll-off acceleration. Only in combination with tilting stage package (except 902)
  • Multi manual dispenser holder
  • Multi automatic dispenser system
  • Large capacity pump dispenser, incl. a 50μl liquid container
  • Surface free energy kit
  • Pendant drop kit (for standard & wide view)
  • Droplet calibration standard (for wide 1 view)
  • Pendant drop kit (for standard & wide view)
  • Kit for captive-bubble-measurements
  • Pendant drop calibration standard (for standard view)
  • Pendant drop calibration standard (for wide 1 and wide 2 view)
Applications
  • Surface cleanliness and homogeneity after cleaning processes (typically for removal of organic contaminations)
  • Surface properties such as wettability and adhesion of modified surfaces and thin film coatings
  • Wetting and dewetting properties in immersion lithography processes using the sliding method with external tilting stage and/or using the extension/contraction method
Specifications
  DMo-902WA DMo-702WA DMo-502WA
Camera system



USB3.0 CMOS camera with:
400fps at 640x480 pixels
500fps at 640x400 pixels
1000fps at 640x200 pixels
Optical system

focus: manual focus with 3 step manual zoom
field of view: 6.1x4.7mm, 11.1x8.2mm, 15.8x11.8mm ±6%
Measuring methods

contact angle: sessile drop (static & dynamic), advancing/receding, tilting1)
surface/interfacial tension: pendant drop (static & dynamic)
Analysis methods



contact angle: θ/2, tangent, curve fitting (ellipse, circle)
surface/interfacial tension: Young-Laplace, ds/de
surface free energy of solids: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range

contact angle: 0.01 to 180°
surface/interfacial tension: 0.01 to 100mN/m
Resolution

contact angle: 0.01°
surface/interfacial tension: 0.01mN/m
Accuracy2)

contact angle: 0.2°
surface/interfacial tension: 0.2mN/m
Maximum sample surface area and height (Dia.xH) max. 300x35mm

Maximum sample weight 400g
Sample stage operation:
X-axis
Y-axis
Z-axis
Rotation axis

150mm (aut.)
---
---
360° (aut.)

150mm (aut.)
---
---
360° (man.)

150mm (man.)
---
---
360° (man.)
Dispenser operation:
Z-axis
Droplet deposition
Droplet generation
Dispensing resolution

35mm
automatic
automatic
0.1μl

35mm
automatic
automatic
0.1μl

35mm
manual
automatic
0.1μl
Measuring temperature ambient
Dimensions (WxDxH) of:
Main instrument
Control box

375x684x432mm
290x240x100mm

375x684x432mm
260x200x70mm
Approximately weight of:
Main instrument
Control box

12.5kg
4.3kg

11.0kg
4.3kg

10.0kg
1.6kg
Electric power:
Voltage
Frequency
Power consumption

AC100-240V
50/60 Hz
115W 120VA

AC100-240V
50/60 Hz
25W 48VA
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

 

 

 

 

PCA-11

The portable contact angle meter PCA11 is a compact and lightweight device for fully automated on-site measurements of contact angle, surface tension, and surface free energy of solids. Testing on-site for quality control and evaluation of surface wettability, which is characterized by the contact angle, is often required during manufacturing processes or in the field. The PCA-11 can be used on any material such as glass, metal, film, paper & pulp, polymer, wood, etc. that have to be measured on-site or that due to their size or shape cannot be analyzed with the usual stationary contact angle measuring instruments. Weighing only 650g, combined with the single-click fully automated operation and its precise measurements, the PCA-11 is the ideal solution for non-destructive surface evaluations.

Features
  • Single-click fully automated operation
  • Precise measurement of contact angles, even on slopes of up to 90º
  • Analysis of surface free energy
  • Measurement of surface tension using the pendant drop method
  • Time-dependent measurements by image capture of up to 30 fps
  • 500 droplets with a volume of 1μl can be generated with one prepared syringe
  • Simple replacement of syringe and liquid sample via the easily accessible front door
  • Visible needle tip allows precise capture of the target point
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options

Hardware

  • Surface free energy kit
  • Pendant drop kit
  • Pendant drop calibration standard (for standard view)
  • Light shielding plate
Applications
  • Evaluation of cleanliness of large panels and silicon wafer
  • Evaluation of surface modification techniques, such as corona, flame and plasma treatments
  • Non-destructive evaluation of hydrophobic and hydrophilic surfaces such as automobiles parts, windshields, building walls
Specifications
  PCA-11
Camera system USB2.0 CMOS camera: 30fps at 640x480 pixels
Optical system

focus: fixed focus with fixed focal length
field of view: 6.3x4.7mm ±5%
Measuring methods

contact angle: sessile drop (static and dynamic)
surface tension: pendant drop (static and dynamic)
Analysis methods



contact angle: θ/2, tangent, curve fitting (ellipse, circle)
surface tension: Young-Laplace, ds/de
surface free energy of solids: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range

contact angle: 0.1 to 180°
surface tension: 0.1 to 100mN/m
Resolution

contact angle: 0.01°
surface tension: 0.01mN/m
Accuracy1)

contact angle: 0.5°
surface tension: 0.5mN/m
Maximum sample surface
area and height (WxDxH)
no limitations

Dispenser operation:
Droplet deposition
Droplet generation
Droplet resolution

automatic
automatic
0.1μl
Dimensions (WxDxH) 110x50x110mm
Approximately weight 650g
Electric power

USB bus power
DC5V, max. 2W
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

 

 

 

 

MCA-4

The MCA-4 uses a precise electric micro-injector system and a high-quality optical system for accurate contact angle measurements of micro-droplets on small surface areas of only 100 x 100µm. With special capillaries available with three different inner diameters, micro-droplets in a range of about 10 to 1000pL can be produced with high reproducibility. This state-of-the-art system is equipped with an additional top-view camera that enables the deposition of droplets with pinpoint accuracy and the observation of the three-phase line and the spreading of micro-droplets on solid surfaces.

Features
  • Fast image capturing system with standard 400 fps at 640x480 resolution USB3.0 CMOS camera, max. 1000fps at 640x200 resolution
  • Automatic recognition of drop deposition by FAMAS analysis software
  • Top view camera allows for deposition of droplets with pinpoint accuracy and for observation of the spreading of micro-droplets
  • The high magnification lens and a 12-fold zoom provide a field of view from approximately 75x56µm to 910x680µm
  • Fine adjustable micro stage in x-, y- and z-axis for exact positioning
  • Fast image capture system allows accurate measurements of even quick evaporating pico-liter droplets
  • Droplet calibration standard bearing three sets of one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options:

Hardware

  • Software-controlled micro-stage
  • Jacket type sample stage for temperature measurements from +10 to +70℃
  • Inkjet head system, using piezoelectric technology to generate droplets from about 8 to 60pL
Applications
  • Miniaturized areas such as of silicon wafer, OLED panels, electronic components, printed circuit boards, etc.
  • Very thin wire materials such as single fibers, hairs, filaments, etc.
  • Defined locations on the surface of tiny samples
  • Ink at very small droplet volume (emitted from an ink-jet head)
  • Other or micro-structured areas where conventional methods and droplet volume are not applicable
Specifications
  MCA-4
Camera system



USB3.0 CMOS camera with:
400fps at 640x480 pixels
500fps at 640x400 pixels
1000fps at 640x200 pixels
Optical system


focus: manual focus with a 12-fold zoom lens
field of view: 75x56μm to 910x680μm ±5%
magnification: 5.3 to 64 times
Measuring methods contact angle: sessile drop (static and dynamic)
Analysis methods


contact angle: θ/2, tangent, curve fitting (ellipse, circle)
surface free energy of solids: Owens-Wendt, Kaelble-Uy, Kitazaki-Hata, Wu, acid-base, Zisman
Measuring range contact angle: 0.1 to 180°
Resolution contact angle: 0.1°
Accuracy1) contact angle: 0.5°
Maximum sample surface area and height (WxDxH) 50x25x5mm

Sample stage operation:
X-axis
Y-axis
Z-axis
manual
25mm
25mm
15mm
Dispenser operation:
X-axis
Y-axis
Z-axis
Droplet generation
Air supply pressure
three-dimensional manual manipulator
30mm
30mm
30mm + 10mm hydraulic micro-manipulator
automatic
0.4 to 0.7 Mpa
Dimensions (WxDxH) of:
Main instrument
Rack for control boxes
Installation area

550x620x700mm
420x320x323mm
1000x650x720mm
Approximately weight of:
Main instrument
Control box

50.0kg
15.0kg
Electric power:
Voltage
Frequency
Power consumption

AC100-240V
50/60 Hz
60W 125VA
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration

 

 

 

 

FPD-CP11

The FPD-CP11 system consists of the main measuring head, a metering pump with a 50mL capacity liquid container, and a control box, and it has been developed for non-contact measurements of contact angles on flat panel displays such as LCD, LED, OLED, and silicon wafer. It has been designed to be attached to metrology systems that combine several different measuring devices in one system. The communication and data transmission between this host system and our FPD-CP11 is achieved via an RS-232C serial port connection.

The system is specially designed to observe droplets with a lateral image capturing system and the optical system is set at a slight angle, making it possible to measure contact angles without having contact with the panel's delicate surfaces. Thanks to this lateral image capturing system, the FPD-CP11 is not limited to only 90º, such as top-view measuring systems, but instead, it delivers high-accuracy and reliable measurements in a range from about 3 to 175º.

Features
  • Single-click automatic measurements, to be operated from a host system
  • Precise and reliable measurement of contact angles from about 3 to 175 degrees
  • Time-dependent measurements by image capture up to 30 fps
  • Metering pump, incl. a 50mL liquid container, allowing 50,000 1μl droplets with one prepared liquid container
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5º, 60º, and 108º for periodic inspection of measurement accuracy
Options
  • No options are available for the FPD-CP11, but customized solutions are possible to adapt the FPD-CP11 to existing metrology systems
Applications
  • Contact angle measurements to determine the surface cleanliness of flat panel displays such as LCD, LED, OLED and silicon wafer
Specifications
  FPD-CP11
Camera system USB2.0 CMOS camera: 30fps at 640x480 pixels
Optical system

focus: fixed focus with fixed focal length
field of view: 6.3x4.7mm ±5%
Measuring methods contact angle: sessile drop (static)
Analysis methods θ/2, tangent, curve fitting (ellipse, circle)
Measuring range 3 to 175°
Resolution 0.1°
Accuracy1) 0.5°
Maximum sample surface area and height (WxDxH) no limitations

Dispenser operation:
Droplet generation
Droplet deposition
Droplet resolution
metering pump, incl. a 50mL liquid container
automatic
automatic
0.1μl
Dimensions (WxDxH) of:
Main instrument
Control box

220x111x305mm
61x75x43mm
Approximately weight of:
Main instrument
Control box

4.0kg
1.5kg
Electric power of:
Main instrument
Control box
USB extension cable

USB bus power, DC5V, max. 2W
AC100-240V, 50/60 Hz, 13W 37VA
AC100-240V, 50/60 Hz, max. 24W 24VA 1A
Operating environment

temperature: +10 to +35℃, humidity: 30-80%RH (non-condensing)
positioned away from sources of electrical noise and vibration