Rapid Thermal Vacuum Process Oven with ramp-up rate up to 150 K/sec.
Technical Data:
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments.
Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool
is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on
a standard laboratory table.
Options and accessories:
| RTP-100 | Basic unit with 1 MFC for Nitrogen (5 nlm) |
| RTP-MFC | Mass Flow controller (max. 4 in total) |
| VAC I | Vacuum up to 3 hPa incl. Vacuum sensor and valve (excl. Pump) |
| VAC II | Vacuum up to 10E-3 hPa incl. Vacuum sensor and valve (excl. Pump) |
| MP | Membrane or diapgrahm pump |
| RVP | Rotary vane pump |
| RTP-Ox | Oxygen measurement |
| RTP-MM | Moisture measurement |
| RTP-H2+H2S | Hydrogen Module to use 100% Hydrogen with safety device incl. MFC |
| RTP-SW | Switchbox for chiller and/or vacuum pump |
| RTP-TC | Add. Thermocouple to measure on device (max. 1 pc) |
| RTP-VCR | VCR connectors and lines (on request) |
| WC III | Closed loop water cooling station |
| RTP-GP | Graphite Plate or suzceptor (SiC coated: on request) |
| RTP-PC-100 | additional oven chamber for usage with one process controller unit (double pack oven) 100 mm |
| RTP-QR-50 | Adapter for 50 mm wafer |
| RTP-QR-75 | Adapter for 75 mm wafer |
Vacuum compliant Rapid Thermal Process Oven with ramp-up rate up to 200 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments. Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on a standard laboratory table.
Options and accessories:
| RTP-100-EP | Basic unit with 1 MFC for Nitrogen (5 nlm) |
| RTP-MFC | Mass Flow controller (max. 4 in total) |
| MP | Membrane or diapgrahm pump |
| RVP | Rotary vane pump |
| RTP-Ox | Oxygen level measurement |
| RTP-MM | Moisture level measurement |
| RTP-H2+H2S | Hydrogen Module to use 100% Hydrogen with safety device incl. MFC |
| RTP-SW | Switchbox for chiller and/or vacuum pump |
| RTP-TC | Add. Thermocouple to measure on device (max. 1 pc) |
| RTP-VCR | VCR connectors and lines (on request) |
| WC III | Closed loop water cooling station |
| RTP-GP | Graphite Plate or suzceptor (SiC coated: on request) |
| RTP-100-PC | additional oven chamber for usage with one process controller unit (double pack oven) 100 mm |
| RTP-QR-50 | Adapter for 50 mm wafer size |
| RTP-QR-75 | Adapter for 75 mm wafer size |
High vacuum compliant Rapid Thermal Process Oven with ramp-up rate up to 150 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments. Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on a standard laboratory table.
Options and accessories:
| RTP-100-HV | Basic unit with 1 MFC for Nitrogen (5 nlm) |
| RTP-MFC | Mass Flow controller (max. 4 in total) |
| MP | Membrane or diapgrahm pump |
| RVP | Rotary vane pump |
| RTP-Ox | Oxygen level measurement |
| RTP-MM | Moisture level measurement |
| RTP-H2+H2S | Hydrogen Module to use 100% Hydrogen with safety device incl. MFC |
| RTP-SW | Switchbox for chiller and/or vacuum pump |
| RTP-TC | Add. Thermocouple to measure on device (max. 1 pc) |
| RTP-VCR | VCR connectors and lines (on request) |
| WC III | Closed loop water cooling station |
| RTP-GP | Graphite Plate or suzceptor (SiC coated: on request) |
| RTP-100-PC | additional oven chamber for usage with one process controller unit (double pack oven) 100 mm |
| RTP-QR-50 | Adapter for 50 mm wafer size |
| RTP-QR-75 | Adapter for 75 mm wafer size |
High vacuum compliant Rapid Thermal Process Oven with ramp-up rate up to 200 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments. Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on a standard laboratory table.
Options and accessories:
| RTP-100-HV-EP | Basic unit with 1 MFC for Nitrogen (5 nlm) |
| RTP-MFC | Mass Flow controller (max. 4 in total) |
| MP | Membrane or diapgrahm pump |
| RVP | Rotary vane pump |
| RTP-Ox | Oxygen level measurement |
| RTP-MM | Moisture level measurement |
| RTP-H2+H2S | Hydrogen Module to use 100% Hydrogen with safety device incl. MFC |
| RTP-SW | Switchbox for chiller and/or vacuum pump |
| RTP-TC | Add. Thermocouple to measure on device (max. 1 pc) |
| RTP-VCR | VCR connectors and lines (on request) |
| WC III | Closed loop water cooling station |
| RTP-GP | Graphite Plate or suzceptor (SiC coated: on request) |
| RTP-100-PC | additional oven chamber for usage with one process controller unit (double pack oven) 100 mm |
| RTP-QR-50 | Adapter for 50 mm wafer size |
| RTP-QR-75 | Adapter for 75 mm wafer size |
Rapid Thermal Vacuum Process Oven with ramp up rate up to 75 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments.
Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool
is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on
a standard laboratory table.
Options and accessories:
| RTP-150 | Basic unit with 1 MFC for Nitrogen (5 nlm = Normliter pro Minute) |
| RTP-MFC | Mass Flow Controller (max. 4 in total) |
| RTP-GP | Graphite plate or susceptor |
| MP | Membrane (Diahragm) Pump up to 10 hPA with manometer |
| RVP | Rotary vane pump system for vacuum up to 10exp.-3 hPa with oil filter and manometer |
| RTP-PC-150 | additional oven chamber for parallel usage with one process controller unit (double pack oven) 150 mm; no simultaneous operation of both chambers possible |
| RTP-QP | Quartz plate |
| RTP-QC-150 | spare quartz chamber for RTP-150 |
| RTP-TC | additional thermocouple to measure on device (plugged in chamber) (max. 3 pcs.) |
| RTP-VM | Vacuum measurement with data logging, up to 10exp.-3 hPa |
| WC III | Closed loop water cooling system |
Rapid Thermal Vacuum Process Oven with ramp up rate up to 150 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments.
Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool
is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on
a standard laboratory table.
Options and accessories:
| RTP-150-EP | Basic unit with 1 MFC for Nitrogen (5 nlm = Normliter pro Minute) |
| RTP-MFC | Mass Flow Controller (max. 4 in total) |
| RTP-GP | Graphite plate or susceptor |
| RTP-PC-150 | additional oven chamber for parallel usage with one process controller unit (double pack oven) 150 mm; no simultaneous operation of both chambers possible |
| RTP-QP | Quartz plate |
| RTP-QC-150 | spare quartz chamber for RTP-150 |
| RTP-TC | additional thermocouple to measure on device (plugged in chamber) (max. 3 pcs.) |
| WC III | Closed loop water cooling system |
| Vacuum | We offer suitable vacuum equipment also vacuum pumps als option (10 hPa up to 10-exp3hPa) High vacuum: see RTP-150-HV) |
High vacuum compliant Rapid Thermal Process Oven with ramp up rate up to 75 K/sec.
Key features are
Multipurpose table top unit with front loading drawer for the following applications:
Technical Data:
The oven will be programmed by a Siemens SPS controller. This allows the storage of 50 programs with saving all temperature profiles and segments.
Options and accessories like water cooler, additional flow meters, additional gas lines, additional thermocouple etc. are available on request. This tool
is for various applications and customers. The small size allows comfortable loading and unloading of the chamber. The oven can be easily placed on
a standard laboratory table.
Options and accessories:
| RTP-150-HV | Basic unit with 1 MFC for Nitrogen (5 nlm = norm liter per minute) |
| RTP-MFC | Mass Flow Controller (max. 4 in total) |
| RTP-GP | Graphite plate or suszeptor |
| RTP-PC-150 | additional oven chamber for parallel usage with one process controller unit (double pack oven) 150 mm; no simultaneous operation of both chambers possible |
| RTP-QP | Quartz plate |
| RTP-QC-150 | spare quartz chamber for RTP-150 |
| RTP-TC | additional thermocouple to measure on device (plugged in chamber), (max. 3) |
| WC III | Closed loop water cooling system |
RTP-200 / RTP-200-HV
Rapid Thermal Process Vacuum oven with or without high vacuum
Technical Specification
• For one single wafer up to 200mm (8") diameter
• With integrated gas in- and outlet
• Maximum temperature: 1000 °C
• Ramp up rate: up to 75 K/sec
• Temperature control by thermocouple (K or S)
• No quartz chamber, aluminium chamber
• Dimensions: about 578 mm x 496 mm x 570 mm (W x D x H)
• Weight: about 70 kg
Part holder
• Quartz tray, fix integrated in door
• Quartz holder for single wafer with 200 mm diameter
Heating
• Heated by 2 x 12 infrared lamps (nominal voltage/power of IR heater: 230 V/2 kW)
• Top and bottom heating (selectable)
Vacuum
• pressure scale 10exp-3 hPa ... 1000 hPa, or 10exp-6 hPa für RTP-200-HV
Process Control
• SPS process controller with 50 programs and up to 50 steps each
(ethernet interface), SIMATIC
• 50 programs each with up to 50 steps can be stored on touch panel
• USB 2.0 interface for storage of process data (in CSV file format)
• Including 7" touch panel for intuitive and comfortable operation
Water cooling
• Water cooling required (inlet pressure: 5 bar, water inlet temperature: 16...20 °C, low water hardness (< 5° dH),
free of Cu particles)
Vacuum Process Oven for up to 300 x 300 mm substrate size and temperature up to 1000 °C
Lamp heated rapid thermal annealing RTA and rapid thermal processing RTP equipment are using lamp heating in order to ramp up and cool down semiconductor wafers pretty fast. This equipment is therefore mainly used for applications where the substrate needs to be brought to a certain temperature just only for short time. The high ramp rates allow a short overall process time and keep the thermal budget (this is the total time of a wafer, being exposed to high temperature) of the wafer low. Because of the design of the heaters, these RTA and RTP tools are used mainly for single wafer treatment. Wafers have to be treated one by one. This is not as important as for other batch thermal processes, which use vertical furnaces and horizontal furnaces, because the process time is very short anyway. However wafer handling takes a substantial part of process time.
The VPO-300 is a cold wall oven.
UniTemp RTP furnaces offer a unique lamp arrangement with upper and lower cross lamp arrays. The temperature distribution tool provides outstanding and unparalleled temperature uniformity resulting in process repeatability.
Application:
Perfect for wafer up to 300 mm or substrates up to 300 x 300 mm.
Through the chamber walls there can be led different feed throughs, like a window for optical measurement tools, thermocouple feed through, gas inlets, etc.
The process cycles are very short due to fast reaching of vacuum with 10E -3 hPa.
Here are the most feasable applications:
Processes using also other contaminating processes possible and all other applications of a RTP/RTA oven are oblitgatory,like:
Chamber:
Loading:
Heating:
Cooling:
Process control:
Process gases:
Vacuum (optional):
Connections:
Dimension/weight:
| VPO-MFC | Mass Flow Controller (max. 3 pcs) |
| VPO-RVP | Rotary vane pump for vacuum up to 10exp.-3 with oil filter |
| VPO-SS | Chamber made of stainless steel instead of Alu (polished) 50 mm |
| VPO-H2 | Hydrogen module |
| VPO-GP | Graphite Plate 3 mm thick |
| VPO-QP | Quartz plate for separation of the top lamp area |
| VPO-QH | Quartz universal holder for 100 mm up to 300 mm wafer size (star) |
| VPO-TC | additional thermocouple to measure on device (plugged in chamber); for external measurement tool max. 4 pcs |
| WC-III | Closed loop water cooling system |
| Vacuum | We offer different vacuum pumps and vacuum equipment |
| VPO-SI | Serial interface between VPO sytem and external PC using USB 2.0 port and through USB 2.0 cable |
| VPO-RC | Remote control of top cover and closing, including connection to safety of external cabinet |
Vacuum Process Oven for up to 300 x 300 mm substrate size and temperature up to 1000 °C)
Lamp heated rapid thermal annealing RTA and rapid thermal processing RTP equipment are using lamp heating in order to ramp up and cool down semiconductor wafers pretty fast. This equipment is therefore mainly used for applications where the substrate needs to be brought to a certain temperature just only for short time. The high ramp rates allow a short overall process time and keep the thermal budget (this is the total time of a wafer, being exposed to high temperature) of the wafer low. Because of the design of the heaters, these RTA and RTP tools are used mainly for single wafer treatment. Wafers have to be treated one by one. This is not as important as for other batch thermal processes, which use vertical furnaces and horizontal furnaces, because the process time is very short anyway. However wafer handling takes a substantial part of process time.
The VPO-300-HV is a cold wall oven.
UniTemp RTP furnaces offer a unique lamp arrangement with upper and lower cross lamp arrays. The temperature distribution tool provides outstanding and unparalleled temperature uniformity resulting in process repeatability.
Application:Processes using also other contaminating processes possible and all other applications of a RTP/RTA oven are oblitgatory,like:
Chamber:
Loading:
Heating:
Cooling:
Process control:
Process gases:
Vacuum:
Connections:
Dimension/weight:
| VPO-MFC | Mass Flow Controller (max. 3 pcs) |
| VPO-RVP | Rotary vane pump for vacuum up to 10exp.-3 with oil filter |
| VPO-SS | Chamber made of stainless steel instead of Alu (polished) 50 mm |
| VPO-H2 | Hydrogen module |
| VPO-GP | Graphite Plate 3 mm thick |
| VPO-QP | Quartz plate for separation of the top lamp area |
| VPO-QH | Quartz universal holder for 100 mm up to 300 mm wafer size (star) |
| VPO-TC | additional thermocouple to measure on device (plugged in chamber); for external measurement tool max. 4 pcs |
| WC-III | Closed loop water cooling system |
| Vacuum | We offer different vacuum pumps and vacuum equipment |
| VPO-SI | Serial interface between VPO sytem and external PC using USB 2.0 port and through USB 2.0 cable |
| VPO-RC | Remote control of top cover and closing, including connection to safety of external cabinet |